/
DE

Turntable-Calibration 4 Items

DJ Turntables 3 HiFi Turntables 1 Portable Record Players 11 Turntable Accessories 9 Dust Covers 2 Turntable Parts 1 Turntable-Calibration 4
Hide Filter & Categories Show Filter & Categories
Filter Results
Manufacturer
Manufacturer
Clearaudio
Ortofon
Close
Price
Price
15 – 30 €
30 – 50 €
100 – 200 €
Close
Artist
Artist
Clearaudio
Ortofon
Close
Back In Stock: 7 Days
Clearaudio - Libelle Basic
Clearaudio
Libelle Basic
25,00 €*
 
Add to Cart Coming Soon Sold out Currently not available Not Enough Coins
Level Gauge - Basic
High precision gauge, calibrated.
Ortofon - Ortofon Stereo Test Record
Ortofon
Ortofon Stereo Test Record
49,00 €*
 
Add to Cart Coming Soon Sold out Currently not available Not Enough Coins
Ortofon’s new Test Record is designed to allow you to verify your HiFi system in the most natural audio surroundings at home. The Test Record contains special test signals developed for analyzing cartridge performance as well as its interaction with your tonearm and turntable.

Before testing your cartridge, please verify the HiFi system’s functionality. The left speaker should be connected to the left amplifier channel and vice versa; both speakers should work in phase and be optimally positioned in the room.
The Test Record is designed to be played through your system with in-built RIAA equalization. Volume control is recommended to be set at a moderate signal level.

Please refer to your turntable and tonearm’s instructions for correct installation and alignment, adjust tonearm to be parallel to record surface, set Vertical Tracking Force and antiskating according to the cartridge’s recommended technical data, and adjust stylus overhang.

The new 15-track fine pressing

Each side of the record consists of 15 tracks which have been cut from 1-4 and 5-15:

1. Frequency Sweep Left Channel 800 Hz – 50 kHz. Log. 28 sec. Linear cut* (800 – 20000 Hz ±1,5 dB)
2. Frequency Sweep Right Channel 800 Hz – 50 kHz. Log. 28 sec. Linear cut* (800 – 20000 Hz ±1,5 dB)
3. Frequency Sweep Left Channel 800 Hz – 50 kHz. Log. 28 sec. Linear cut* (800 – 20000 Hz ±1,5 dB)
4. Frequency Sweep Right Channel 800 Hz – 50 kHz. Log. 28 sec. Linear cut* (800 – 20000 Hz ±1,5 dB)
5. Reference tone 1000 Hz 5 cm/sec rms Left
6. Reference tone 1000 Hz 5 cm/sec rms Right
7. Reference tone 1000 Hz 5 cm/sec rms Left
8. Reference tone 1000 Hz 5 cm/sec rms Right
9. Tracking ability, lateral 50 ?m peak
10. Tracking ability, lateral 60 ?m peak
11. Tracking ability, lateral 70 ?m peak
12. Tracking ability, lateral 80 ?m peak
13. Tracking ability, lateral 90 ?m peak
14. Tracking ability, lateral 100 ?m peak
15. Square Wave Form 2.7 msec duty cycle 3:7
* The record has a constant velocity amplitude throughout the sweep.

1-4 Frequency sweep – a tool for checking frequency response
There are several factors which can affect frequency response, including cable capacitance, cartridge loading, tracking force and worn parts. Because of this, it can be difficult to achieve perfectly flat frequency response. Sometimes by making small compromises in the cartridge loading, a better overall frequency response can be achieved. Considering the above the signal must be clean throughout the sweep.

5-8 Reference tone for testing channel output
With this standard reference signal is it possible to check the correctness of the connections of the left and right channels, channel balance and speed of the turntable.

9 -14 Tracking ability test, 315 Hz lateral modulation
These tracks contain a 315 Hz signal, recorded at increasing pick amplitudes of 50, 60, 70, 80, 90 and 100 micrometers. Please refer to your cartridge’s tracking ability value specified in the technical data sheet. Your cartridge should be able to track the actual level without audible distortion. Inability to track can be heard as a departure from a pure tone or a sputtering and intermittent tone. To determine if it is one or both channels, the balance control can be utilized. In case of differing tracking ability in the left and right channels it is probably necessary to readjust the anti-skating correction of the tonearm. If both channels fail to track properly, then vertical tracking force should be increased until no further improvement of tracking force can be obtained.

15. Square Wave Form 2.7 msec duty cycle 3:7
When monitoring the output of your cartridge with an oscilloscope you’ll then see a square wave located precisely above each other if the connection from the cartridge is correct.

After successful completion of the above test procedures, you can ensure that your cartridge is optimized. Still the human ear is very sensitive to difference in tone distortion; its level depends on the stylus condition and record wear.

To maintain optimal sound reproduction and to minimize wear on your records as well as on your stylus, we recommend the following procedure before and after each playback:
• Remove dust carefully from record surfaces by using a fine antistatic brush or cloth before every use.
• Please remember to remove dust from the diamond tip before and after playback of each record
• I order to keep electrical contacts clean and to lubricate the knurled nut on the tonearm, Ortofon recommends occasionally a light spray of contact cleaner like DeoxIT ®Gold G-Series into the tonearm socket.

It should be noted that some phono equalizers may generate some tone distortion, which cannot be referred to the cartridge.

User Guide: https://www.ortofon.com/media/148619/ortofon-test-record-user-guide.pdf
Clearaudio - Speed Light V2
Clearaudio
Speed Light V2
150,00 €*
 
Add to Cart Coming Soon Sold out Currently not available Not Enough Coins
Quartz controlled 300 Hz light source

Enables exact adjustment of your turntable speed by keeping the light source independent from fluctuations in the mains frequency and voltage, which would otherwise give distorted results. A quartz oscillator generates an accurate 300 Hz, white light source, making precise speed adjustment easy when used in conjunction with the Clearaudio Stroboscopic Testrecord.

An optimal listening experience requires precise settings, especially when it comes to motor speed. The clearaudio Speed Light V2 is your key to accurate speed adjustments, regardless of the power grid frequency in your country. In this enhanced version, we present an upgrade for ultimate precision and user-friendliness.

New features at a glance:

White LED for improved visibility:
The transition from a blue LED to a white LED ensures an even better visibility of the line pattern on the stroboscopic disc. Every pulse is accurately captured, allowing for precise speed adjustments.

Extended operating time with a new battery:
The switch to the lithium button cell (CR2023) not only provides a longer operating time but also ensures a constant power supply for reliable performance. The Speed Light V2 does not have a rechargeable battery and operates only on a battery or continuous power.

New Micro-USB port for battery-independent operation:
The implementation of a Micro-USB port offers the option of battery-independent operation.

Aluminum casing:
The casing, milled from solid material and made of anodized aluminum, replaces the previous plastic, improving durability and adding an aesthetically pleasing element.

Compatible with the Stroboscopic Test Record:
The clearaudio Speed Light V2 is perfectly tuned for use with our Stroboscopic Test Record.

Manual: https://www.clearaudio.de/_assets/_pdf/manuals/accessories/CA_Speed%20light%20V2_E+D.pdf
Clearaudio - Speed Light V2 + Stroboscope Speed Test Record
Clearaudio
Speed Light V2 + Stroboscope Speed Test Record
190,00 €*
 
Add to Cart Coming Soon Sold out Currently not available Not Enough Coins
Providing unbeatable accuracy! The Stroboscope Testrecord together with the Speed Light V2 give the best results in adjusting your turntable speed.

Enables exact adjustment of your turntable speed by keeping the light source independent from fluctuations in the mains frequency and voltage, which would otherwise give distorted results. A quartz oscillator generates an accurate 300 Hz, white light source, making precise speed adjustment easy when used in conjunction with the Clearaudio Stroboscopic Testrecord.

An optimal listening experience requires precise settings, especially when it comes to motor speed. The clearaudio Speed Light V2 is your key to accurate speed adjustments, regardless of the power grid frequency in your country. In this enhanced version, we present an upgrade for ultimate precision and user-friendliness.

New features at a glance:

White LED for improved visibility:
The transition from a blue LED to a white LED ensures an even better visibility of the line pattern on the stroboscopic disc. Every pulse is accurately captured, allowing for precise speed adjustments.

Extended operating time with a new battery:
The switch to the lithium button cell (CR2023) not only provides a longer operating time but also ensures a constant power supply for reliable performance. The Speed Light V2 does not have a rechargeable battery and operates only on a battery or continuous power.

New Micro-USB port for battery-independent operation:
The implementation of a Micro-USB port offers the option of battery-independent operation.

Aluminum casing:
The casing, milled from solid material and made of anodized aluminum, replaces the previous plastic, improving durability and adding an aesthetically pleasing element.

Manual: https://www.clearaudio.de/_assets/_pdf/manuals/accessories/CA_Stroboscope%20Testrecord%20+%20Speedlight_E+D.pdf
Back To Top